The automatic digital display medical gas manifold is consisted of a centralized battery of cylinders, complete with support tacks, headers, automatic manifold distribution panels and all necessary controls, safety devices, alarms, pipework, valves and terminal units for distributing the gases to the required positions as listed on the schedule of terminal units.
The automatic digital display medical gas manifold is consisted of a centralized battery of cylinders, complete with support tacks, headers, automatic manifold distribution panels and all necessary controls, safety devices, alarms, pipework, valves and terminal units for distributing the gases to the required positions as listed on the schedule of terminal units.
Features
· Fully enclosed metal box, anti-interference;
· Stainless steel diaphragm pressure reducer to ensure stable flow;
· LED display system status ("in use"-green; "standby"-yellow; "change bottle"-red)
· With alarm device, it can also alarm remotely;
· Open design to meet future expansion needs;
· Compact structure and reasonable layout;
· Secondary pressure reducing structure, stable output pressure;
· The piping system adopts silver welding to effectively prevent leakage;
· The unique switching valve design ensures that the gas is continuously stable during the switching between the main gas supply cylinder group and the backup bottle group;
· Built-in gas filter, can effectively filter the dust in the gas;
· Reliable wall installation or horizontal installation;
· With wall mounted bracket/chain to stable the oxygen cylinder;
· Degreasing and cleaning according to CGA4.1 and ISO 15001 standards, oxygen is suitable for 100% pressure test of the whole system, safe and reliable;
· High-pressure hose adopts bull nose metal hose;
· Input 110VAC to 240VAC, 50-60Hz
Model Number |
Pressure monitor |
Inlet max Pressure |
Delivery Pressure |
Delivery Flow |
Inlet port |
Outlet port |
Power |
|
Level |
psi |
|||||||
GMS-DL-02 |
Digital |
3000 |
Lower |
55 |
3500 |
1"- 11 1/2 |
3/4 |
100 ~ 240 |
GMS-DM-02 |
Middle |
100 |
||||||
GMS-DH-02 |
Higher |
185 |
||||||
GMS-DL-AIR |
Lower |
55 |
||||||
GMS-DM-AIR |
Middle |
100 |
||||||
GMS-DL-N20 |
Lower |
55 |
1000 |
|||||
GMS-DM-N20 |
Middle |
100 |
||||||
GMS-DL-CO2 |
Lower |
55 |
||||||
GMS-DM-CO2 |
Middle |
100 |
||||||
GMS-DH-C02 |
Higher |
185 |
||||||
GMS-DM-IAIR |
Middle |
100 |
||||||
GMS-DH-IAIR |
Higher |
185 |
||||||
GMS-DL-NIT |
Lower |
55 |
||||||
GMS-DM-NIT |
Middle |
100 |
||||||
GMS-DH-NIT |
Higher |
185 |
||||||
GMS-DL-IN |
Lower |
55 |
||||||
GMS-DMM-N |
Middle |
100 |
||||||
GMS-DH-IN |
Higher |
185 |